Data format:

One line with 2 parameters followed by two lines with one parameter each.

INOD ITYP
DLLFileName
DLLProcName

Status :

Optional

Restriction :

For dynamic analyses only.

Purpose :

To impose a motion or a displacement on a node

Details :

Parameter Description
INOD Node of the low shaft linked to the drive train.
ITYP Type of control : 0 force; 1 :displacement
DLLFileName DLL file name
DLLProcName DLL procedure name

Note

Procedure in the DLL exchanges the following information with DeepLines at the beginning of each timestep : (vec, pos, vit, acce, t, dt) where

  • vec is a double precision real vector of length 6. The procedure provides displacement or force to be applied on the 6 degrees of freedom

  • pos is a double precision real vector of length 6. DeepLines provides the position of the six degrees of freedom of the node

  • vit is a double precision real vector of length 6. DeepLines provides the velocity of the six degrees of freedom of the node

  • acce is a double precision real vector of length 6. DeepLines provides the acceleration of the six degrees of freedom of the node

  • t : time provided by DeepLines