Skip to content

*NODECONT,NAME=YAWSTAT

Data format:

One line with 2 parameters followed by one line with 2 parameters

INOD ITYP
ANG NSTART NEND

Status :

Optional

Purpose :

To rotate a node around the Z-axis of its master node of ANG degrees in static linearly between 0 and NSTEP

Details :

Parameter Description
INOD Node where the control is applied.
ITYP Type of control. This parameter must be set to 1.
ANG Value of the rotation angle about the Z-axis of the master node (degrees). Warning: Angle values must be between -180 degrees to +180 degrees.
NSTART Step number to start the rotation
NEND Step number to end the rotation