Skip to content

Home > List of Keywords > *NODECONT,NAME=TUSIM

*NODECONT,NAME=TUSIM

Data format:

One line with 2 parameters followed by one line 1 parameter

IDHUB IOP
IDTURB

Status :

Optional

Restriction :

For dynamic analysis only

Purpose :

To use a simplified turbine model

Details :

Parameter Description
INOD Controlled node, the node must be the turbine hub master node
ITYP Type of control = 1 : displacement
IDTURB The turbine ID number

Notes : This option must be used in conjunction with a simplified blades (rigid or modal approach) together with *WTHUB to rotate the turbine.