Home > List of Keywords > *NODECONT,NAME GENERATOR
*NODECONT,NAME=GENERATOR
Data format:
One line with 2 parameters followed by one line 12 parameters
INOD ITYP
ID INOREAC GBRATIO GBEFF STIFF DAMP POWER MTRL MINGT MAXGT EFF IEFF
Status :
Optional
Restriction :
The generator node and a turbine must be previously defined. For dynamic analyses only.
Purpose :
To define an electric generator
Details :
Parameter | Description |
---|---|
INOD | Node of the low shaft linked to the drive train. |
ITYP | type of control : 0 force |
ID | Identification numer of the Wind Turbine component. |
INOREAC | Point where the reaction moment (opposite of the imposed moment) is applied |
GBRATIO | Ratio of the GEARBOX (winput/woutput), 1 if no gearbox |
GBEFF | Gearbox efficiency, 1 if no gearbox. If the efficiency is less or equal 0 or strictly greater than 1, it is considered that the gearbox efficiency is function of the velocity. The efficiency is then defined by a predefined table (*TABLEMCOL) which number is defined by IEFF |
STIFF | Rotational stiffness of Gearbox + HSS : This is not used and should be defined (added) to the shaft properties. |
DAMP | Rotational damping of Gearbox +HSS : This is not used and should be defined (added) to the shaft properties. |
POWER | Generator power (W) |
MTRL | Maximum torque rate limit (N.m.s-1) |
MINGT | Minimum generator torque (N.m) |
MAXGT | Maximum generator torque (N.m) |
EFF | Generator efficiency |
IEFF | If GBEFF is less than 0, the gearbox efficiency is defined by a table, the table ID is IEFF |