Skip to content

Home > List of Keywords > *FONDATION

*FONDATION

Data format:

A single line with a maximum of NGR+2 values (NGR is the number of casings in the foundation):

ID IGR_1 ... IGR_NGR Depth

Status :

Optional

Purpose :

To define a Drilling riser foundation.

Restriction :

CASING groups must be previously defined.

Details :

Parameter Description
ID ID number of the foundation
IGR1 Most external casing
...
IGR_NR Most internal casing
DEPTH If not defined, the DEPTH defined is used. Otherwise a specific depth can be defined for the soil at the foundation. The value must be negative