Home > List of Keywords > *FLOATFIL,NAME=Floater_Name

*FLOATFIL,NAME=Floater_Name

Data cards :

One line with three parameters:

PER FILY FILP

Status :

Optional

Restriction :

A floater must be previously defined (for dynamic analysis only)

Purpose :

To adapt the filtering of the floater yaw or position to evaluate wave loads (from HDB file)

Details :

Floater_name is the name of a floater in the analysis defined by a *FPFDX keyword

Parameter Description
PER Cut-off frequency for the low pass filter(s) - default is 60s
FILY Option for filtering in yaw (used to compute the direction )
= 0 : Filtering
= 1 : No Filtering, instantaneous value is used
= 2 value at the end of static used
FILP Option for filtering in position (used to compute the phase of the hydrodynamic loads)
= 0 : Filtering
= 1 : No Filtering, instantaneous value is used
= 2 value at the end of static used