Home > List of Keywords > *FLOATFIL,NAME=Floater_Name
*FLOATFIL,NAME=Floater_Name
Data cards :
One line with three parameters:
PER FILY FILP
Status :
Optional
Restriction :
A floater must be previously defined (for dynamic analysis only)
Purpose :
To adapt the filtering of the floater yaw or position to evaluate wave loads (from HDB file)
Details :
Floater_name is the name of a floater in the analysis defined by a *FPFDX keyword
Parameter | Description |
---|---|
PER | Cut-off frequency for the low pass filter(s) - default is 60s |
FILY | Option for filtering in yaw (used to compute the direction ) = 0 : Filtering = 1 : No Filtering, instantaneous value is used = 2 value at the end of static used |
FILP | Option for filtering in position (used to compute the phase of the hydrodynamic loads) = 0 : Filtering = 1 : No Filtering, instantaneous value is used = 2 value at the end of static used |