Home > List of Keywords > *DAMPVIV
*DAMPVIV
Data format:
An arbitrary number of rows with 2 parameters, as follows:
EFF ELENB
...
Status:
Optional.
Purpose:
To define the efficiency of VIV suppression devices and associated List ofelements.
Restriction:
The elements to which VIV suppression devices efficiency is assigned must have been previously defined.
Details :
Parameter | Description |
---|---|
EFF | Efficiency of the VIV suppression device. The efficiency must be a real value between 0 (no reduction in lift force) and 1 (100% efficiency with zero lift force). Note: The efficiency rate of usual strakes is about 90% which means that the original lift coefficient (CL) curve function of the amplitude over diameter ratio (A/D) is factored by (1-0.9). You should set the efficiency of the VIV suppression device to 0.9 in this case. |
ELENB | Identification numbers of the elements where the VIV suppression device shall be accounted for. Example: Assigning a VIV suppression device efficiency of 90% to elements 10 to 15 could write either: DAMPVIV 0.9 10 11 12 13 14 15 or DAMPVIV 0.9 10 - 15 |