Skip to content

Home > List of Keywords > *COADIR

*COADIR

Data format:

One line with 8 parameters, as follows:

IPRO ITYP CDP CDM CAP CAM CMP CMM

Status:

Optional.

Restriction:

An element property must be previously defined.

Purpose:

To define hydrodynamic coefficients (drag, added mass and inertia) function of the direction of the fluid-structure velocity along an element axis. This allows setting different hydrodynamic coefficients function of the direction of the relative axial fluid velocity with respect to the orientation of the line. Positive direction is from End1 towards End2 where End1 and Enad2 are the first and last node of the element respectively

Details:

Parameter Description
IPRO Identification number of a previously defined property with *CABPRO, *BEAMPRO, *RIGIPRO, *BARPRO
ITYP Type of property.
ITYP = 1: cable (*CABPRO)
ITYP = 2: beam (*BEAMPRO, *RIGIPRO)
ITYP = 3: bar (*BARPRO)
CDP Drag coefficient for positive velocity
CDM Drag coefficient for negative velocity
CAP Added mass coefficient for positive velocity
CAM Added mass coefficient for negative velocity
CMP Inertia coefficient for positive velocity
CMM Inertia coefficient for negative velocity