Home > List of Keywords > *CLVIVRE
*CLVIVRE
Data format:
One 1 line with 1 parameter followed by NL lines with 2 parameters each, as follows:
NL
RE(1) CL(1)
RE(2) CL(2)
...
RE(NL) CL(NL)
Status:
Optional.
Restriction:
Used with a modal VIV analysis.
Purpose :
To define a lift coefficient (CL) curve function of the Reynolds number (Re).
Details:
Parameter | Description |
---|---|
NL | Number of lines to read. This is the number of (RE,CL) couples. |
RE(1) | Cross-flow vibration amplitude over line diameter ratio A/D(1) |
CL(1) | Lift coefficient CL(1) associated with RE(1) |
... | ... |
RE(NL) | Cross-flow vibration amplitude over line diameter ratio RE(NL) |
CL(NL) | Lift coefficient CL(NL) associated with RE(NL) |
Note
the curve is multiplied by the curve defined by *CLVIVAD if defined.